DocumentCode
534508
Title
Constructing a human eye model: The cornea shape effect on optical imaging for the human eyes
Author
Feng, Jihong ; Zhang, Hanyu ; Wang, Xiaobing ; Liu, Aizhen
Author_Institution
Coll. of Life Sci. & Bioeng., Beijing Univ. of Technol., Beijing, China
Volume
1
fYear
2010
fDate
16-18 Oct. 2010
Firstpage
171
Lastpage
173
Abstract
This paper study the effect of cornea shape on optical imaging of the human eyes for future constructing a human eye model using ray tracing method in optical design software Zemax. Theoretical calculation results show that geometric image is best when the cornea´s front surface radius being 7.8mm and gets bad away from 7.8mm. When the cornea´s front surface radius is 7.8±0.015mm, the image can´t be recognized. Further, calculation RMS radius shows the radius is smallest when the cornea´s front surface radius being 7.8mm and gets big when away from 7.8mm.
Keywords
eye; optical images; Zemax software; cornea shape effect; human eye model; optical imaging; Cornea; Humans; Lenses; Optical imaging; Optical refraction; Optical surface waves; Optimized production technology; Human eye model; geometric image analysis; ray tracing; root mean square (RMS);