Title :
Determination of Odor Compounds by Using Headspace Solid-Phase Micro Extraction Combined with GC-MS
Author :
Zhang, Yan ; Chen, Jiao ; Yang, Yanling ; Li, Xing
Author_Institution :
Key Lab. of Beijing for Water Quality Sci. & Water Environ. Restoration, Beijing Univ. of Technol., Beijing, China
Abstract :
Geosmin (GSM) and 2-methyl isoboneol(2-MIB) are the major compounds causing the odor of water body. A new method for the qualitative and quantitative analysis of GSM and 2-MIB, which isolated and enriched the odor compounds from the water samples by using Headspace solid-phase micro extraction (HS-SPME), and detected the two substances using GC/MS with internal standard method, was developed. The optimal conditions of HS-SPME for GSM and 2-MIB were as follow: extracting for 40minute, extracting at 65°C, and adding NaCl 0.1g. The temperature program for column of GC was first maintained at 50 °C for 1 minute, then rose to 100 °C at the rate of 10°C per minute keeping for 0.15minute, finally rose to 240°C by 5°C per minute. Under these conditions, the separate detection limits of GSM and 2-MIB were obtained with 0.2ng / L and 0.5ng / L. The relative standard deviations were 5.37% and 5.56% respectively. This method applied for measuring the actual water samples of Longtan Lake and Taihu Lake in December. The former contained 1.26ng/L of GSM and 1.074ng/L of 2-MIB, while the latter included 2.681ng/L of GSM and 3.392ng/L of 2-MIB.
Keywords :
chemical technology; water pollution control; water resources; 2-methyl isoboneol; Headspace solid-phase microextraction; Longtan lake; Taihu lake; geosmin; odor compound determination; Cities and towns; Compounds; Educational institutions; GSM; Lakes; Microorganisms; Monitoring;
Conference_Titel :
E-Product E-Service and E-Entertainment (ICEEE), 2010 International Conference on
Conference_Location :
Henan
Print_ISBN :
978-1-4244-7159-1
DOI :
10.1109/ICEEE.2010.5660538