DocumentCode
539059
Title
Full-wave investigation of EFT injection clamp calibration setup
Author
Caniggia, Spartaco ; Dudenhoeffer, Eric ; Maradei, Francescaromana
fYear
2010
fDate
25-30 July 2010
Firstpage
602
Lastpage
607
Abstract
The paper deals with a full-wave investigation of the capacitive coupling clamp that is used in electrical fast transient (EFT) immunity test to inject disturbances to nominal signals. The analysis is performed by using the software tool MicroWave Studio (MWS) based on the finite integration technique. The model of the injection clamp is validated by comparison with measurements and with the results obtained by SPICE. The full-wave model is used to investigate EFT injection clamp calibration setup, such as that proposed in section “6.4.2 Calibration of the capacitive coupling clamp” of the IEC 61000-4-4 new Edition (i.e., the 3rd).
Keywords
IEC standards; SPICE; calibration; transients; EFT injection clamp calibration setup; IEC 61000-4-4; MicroWave Studio; SPICE; capacitive coupling clamp; electrical fast transient immunity test; finite integration technique; full-wave investigation; full-wave model; software tool; Cable shielding; Calibration; Clamps; Couplings; Integrated circuit modeling; Load modeling; SPICE; Electrical Fast Transient/burst (EFT/B); Microwave Studio; SPICE; finite integration technique (FIT); full-wave analysis; immunity;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
Conference_Location
Fort Lauderdale, FL
ISSN
2158-110X
Print_ISBN
978-1-4244-6305-3
Type
conf
DOI
10.1109/ISEMC.2010.5711345
Filename
5711345