• DocumentCode
    539059
  • Title

    Full-wave investigation of EFT injection clamp calibration setup

  • Author

    Caniggia, Spartaco ; Dudenhoeffer, Eric ; Maradei, Francescaromana

  • fYear
    2010
  • fDate
    25-30 July 2010
  • Firstpage
    602
  • Lastpage
    607
  • Abstract
    The paper deals with a full-wave investigation of the capacitive coupling clamp that is used in electrical fast transient (EFT) immunity test to inject disturbances to nominal signals. The analysis is performed by using the software tool MicroWave Studio (MWS) based on the finite integration technique. The model of the injection clamp is validated by comparison with measurements and with the results obtained by SPICE. The full-wave model is used to investigate EFT injection clamp calibration setup, such as that proposed in section “6.4.2 Calibration of the capacitive coupling clamp” of the IEC 61000-4-4 new Edition (i.e., the 3rd).
  • Keywords
    IEC standards; SPICE; calibration; transients; EFT injection clamp calibration setup; IEC 61000-4-4; MicroWave Studio; SPICE; capacitive coupling clamp; electrical fast transient immunity test; finite integration technique; full-wave investigation; full-wave model; software tool; Cable shielding; Calibration; Clamps; Couplings; Integrated circuit modeling; Load modeling; SPICE; Electrical Fast Transient/burst (EFT/B); Microwave Studio; SPICE; finite integration technique (FIT); full-wave analysis; immunity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
  • Conference_Location
    Fort Lauderdale, FL
  • ISSN
    2158-110X
  • Print_ISBN
    978-1-4244-6305-3
  • Type

    conf

  • DOI
    10.1109/ISEMC.2010.5711345
  • Filename
    5711345