• DocumentCode
    544722
  • Title

    Fuzzy control of postoperative pain

  • Author

    Hernández, C. ; Carollo, A. ; Tobar, A. ; Bóveda, C.

  • Author_Institution
    Department of Applied Physics. Faculty of Physics. University of Santiago
  • Volume
    6
  • fYear
    1992
  • fDate
    Oct. 29 1992-Nov. 1 1992
  • Firstpage
    2301
  • Lastpage
    2303
  • Abstract
    Post-operative pain is difficult to model, this difficulty being due to non-linearity, time varying behavior and intro and inter-patient variability. In this study, we describe the application of a two-stage fuzzy controller in the relief of post-operative pain. In the first stage, a fuzzy system operates until the required set-point (i.e. no pain) is attained, following which a CACI system, operating about the set-point, is used to avoid an increasing plasma concentration of opiate. The controller has been implemented in OPS-83 and in Microssoft-C.
  • Keywords
    Adaptation model; Biological system modeling; Pain; Plasmas; Silicon; Time measurement; fuzzy control; pain; rule-based systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
  • Conference_Location
    Paris, France
  • Print_ISBN
    0-7803-0785-2
  • Electronic_ISBN
    0-7803-0816-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1992.5761472
  • Filename
    5761472