DocumentCode
545262
Title
High resolution anatomic model fabrication from CT: Visualizing 3-D error
Author
Mankovich, Nicholas J. ; Hiller, John ; Hallinan, John ; Nicholls, John ; Dennis, Martin
Author_Institution
Department of Radiological Sciences, Olive View - UCLA Medical Center, Los Angeles, CA
Volume
5
fYear
1992
fDate
Oct. 29 1992-Nov. 1 1992
Firstpage
2073
Lastpage
2075
Abstract
A new CAM rapid prototype technology is being used to produce life-size anatomic models for custom prosthesis design and surgical planning. An 80 slice CT study was used to produce three bone models with stereolithography, each employing variations in solid models derived from segmented CT data. The error in linear measurements between the CT data and the fabricated model is discussed and a procedure involving a secondary CT scan of the plastic fabricated model and subsequent registration and visualization of error is presented.
Keywords
Computed tomography; Computer aided manufacturing; Numerical models; Plastics; Positron emission tomography; Registers; Visualization;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
Conference_Location
Paris, France
Print_ISBN
0-7803-0785-2
Electronic_ISBN
0-7803-0816-6
Type
conf
DOI
10.1109/IEMBS.1992.5762174
Filename