    Demo abstract: Closed-loop testing for implantable cardiac pacemakers

  • Author

    Jiang, Zhihao ; Pajic, Miroslav ; Mangharam, Rahul

  • Author_Institution
    Dept. Electr. & Syst. Eng., Univ. of Pennsylvania, Philadelphia, PA, USA
  • fYear
    2011
  • fDate
    12-14 April 2011
  • Firstpage
    119
  • Lastpage
    120
  • Abstract
    The increasing complexity of software in implantable medical devices such as cardiac pacemakers and defibrillators accounts for over 40% of device recalls. Testing remains the principal means of verification in the medical device certification regime. Traditional software test generation techniques, where the tests are generated independently of the operational environment, are not effective as the device must be tested within the context of the patient´s condition and the current state of the heart. It is necessary for the testing system to observe the system state and adaptively generate the next input to advance the purpose of the test. To this effect, a set of general and patient condition-specific temporal requirements is specified for the closed-loop heart and pacemaker system. Based on these requirements, we implemented a closed-loop testing platform between a timed automata based heart model on a FPGA board and a pacemaker on a micro-controller. This allows for interactive and physiologically relevant model-based test generation for basic pacemaker device operations such as maintaining the heart rate and atrial-ventricle synchrony. We also demonstrate the flexibility and efficacy of the testing platform for more complex common timing anomalies such as reentry circuits, pacemaker mode switch operation and pacemaker-mediated tachycardia. This system is a step toward a testing approach for medical cyber-physical systems with the patient-in-the-loop.
  • Keywords
    automata theory; cardiology; field programmable gate arrays; medical control systems; medical disorders; microcontrollers; pacemakers; physiological models; program testing; program verification; FPGA board; atrial-ventricle synchrony; closed-loop testing; defibrillators; heart; heart rate; implantable cardiac pacemakers; implantable medical devices; medical device certification; microcontroller; pacemaker mode switch operation; reentry circuits; software test generation techniques; tachycardia; timed automata; Biological system modeling; Heart; Pacemakers; Real time systems; Safety; Software; Testing; Real-time systems; cyber-physical systems; medical devices;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Processing in Sensor Networks (IPSN), 2011 10th International Conference on
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    978-1-61284-854-9
  • Electronic_ISBN
    978-1-4503-0512-9
  • Type

    conf

  • Filename
    5779074