DocumentCode
546487
Title
Detection of permeabilisation obtained by micropulses and nanopulses by means of bioimpedance of biological tissues
Author
Silve, Aude ; Ivorra, Antoni ; Mir, Lluis M.
Author_Institution
Inst. Gustave Roussy, Villejuif, France
fYear
2011
fDate
11-15 April 2011
Firstpage
3164
Lastpage
3167
Abstract
In this paper permeabilisation of potato tissue caused by either microsecond electric pulses or nanosecond electric pulses is compared. The intensity of permeabilisation is quantified by means of bio-impedance change. Thanks to this method, the impact of the repetition frequency was investigated. Data show that very low repetition frequencies can be much more efficient to permeabilise.
Keywords
bioelectric phenomena; biological effects of fields; biological tissues; permeability; bioimpedance; biological tissues; microsecond electric pulses; nanosecond electric pulses; permeabilisation; potato tissue; repetition frequency; Bioimpedance; Impedance; Impedance measurement; In vivo; Nanobioscience; Permeability measurement; Pulse measurements;