DocumentCode
548179
Title
A Contactless Power Supply System for Intra-corporeal Medical Instrumentations
Author
Xuan, Yanjiao ; Gu, Kaiyun ; Gao, Bin ; Chang, Yu
Author_Institution
Sch. of Life Sci. & Bioeng., Beijing Univ. of Technol., Beijing, China
Volume
1
fYear
2011
fDate
14-15 May 2011
Firstpage
3
Lastpage
6
Abstract
At present, most of power supply systems for intracorporeal medical instrumentations adopt internal power storage mode or transcutaneous energy transmission system. However, both patterns have some disadvantages: internal power storage mode cannot supply long-term power so that this mode limits the continuity of total system; infection is easily generated in a transcutaneous energy transmission system which brings numerous inconveniences to patients. In order to solve these problems, a novel contactless power supply system designed by our group, which transmits electric power for intracorporeal medical instrumentations from outside of the skin to inside. The novel power supply system consists of a pair of coupling permanent magnets mounted on a motor and a subminiature generator respectively. After electricity passes through a voltage doubling rectification circuit and a filter circuit, it is able to charge a battery pack and provide energy for intracorporeal medical instrumentations, such as blood pump. Output voltage (5.5v-10.5v) of this system has achieved the requirement of high safety. With a variation of input voltage from 12v to 13v, output voltage is stable relatively. And at the point of 12v, maximum efficiency is obtained. This system doesn´t need external wire connection and avoids infection. Furthermore, this equipment of power supply expands the freedom of patients, doing certain activities and improving their life qualities.
Keywords
biomedical electronics; biomedical equipment; electric motors; filters; patient treatment; permanent magnets; prosthetic power supplies; rectification; rectifying circuits; skin; battery pack; blood pump; contactless power supply system; coupling permanent magnets; filter circuit; infection; internal power storage mode; intracorporeal medical instrumentations; life quality; medical implantable instrumentation; motor; skin; subminiature generator; transcutaneous energy transmission system; voltage doubling rectification circuit; Couplings; Generators; Instruments; Magnetic circuits; Magnetic separation; Power supplies; Rotors; contactless power supply; energy transmission; intracoporeal; magnetic coupling; medical instrumentations;
fLanguage
English
Publisher
ieee
Conference_Titel
Multimedia and Signal Processing (CMSP), 2011 International Conference on
Conference_Location
Guilin, Guangxi
Print_ISBN
978-1-61284-314-8
Electronic_ISBN
978-1-61284-314-8
Type
conf
DOI
10.1109/CMSP.2011.9
Filename
5957361
Link To Document