• DocumentCode
    548541
  • Title

    Gateway design and implementation in an Automatic Meter Reading system based on Power Line Communications

  • Author

    Popa, M.

  • Author_Institution
    Fac. of Autom. & Comput., Politeh. Univ., Timisoara, Romania
  • fYear
    2011
  • fDate
    21-23 June 2011
  • Firstpage
    295
  • Lastpage
    298
  • Abstract
    Automatic Meter Reading (AMR) means to automatically collect data from different kinds of meters. In this way consumption of water, gas and energy can be remotely measured. This paper describes an AMR system based on Power Line Communications. Smart meters are connected through a LonWork type industrial bus to a Gateway. The Gateway sends messages to the meters and reads the collected data. It communicates, through GSM, with a Data Acquisition Center (DAC) were data is processed. The software part of the gateway is focused.
  • Keywords
    automatic meter reading; carrier transmission on power lines; cellular radio; computerised instrumentation; data acquisition; internetworking; GSM; LonWork type industrial bus; automatic meter reading system; data acquisition center; gateway design; power line communications; smart meters; Automatic meter reading; Buildings; Logic gates; Power line communications; Protocols; Sensors; Software;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Networked Computing and Advanced Information Management (NCM), 2011 7th International Conference on
  • Conference_Location
    Gyeongju
  • Print_ISBN
    978-1-4577-0185-6
  • Electronic_ISBN
    978-89-88678-37-4
  • Type

    conf

  • Filename
    5967563