DocumentCode :
549923
Title :
Update on partial discharge screening tests for stator bars & coils
Author :
McDermid, W. ; Bromley, J.C. ; Black, T.
Author_Institution :
Manitoba Hydro, Winnipeg, MB, Canada
fYear :
2011
fDate :
5-8 June 2011
Firstpage :
20
Lastpage :
22
Abstract :
In 1992 a paper examined evidence of a relationship between measured partial discharge and subsequent voltage endurance of certain stator bars. The PD test method utilizes a higher frequency range than the conventional 30 kHz to 400 kHz and may be more appropriate for the detection of internal voids. More recently there have been other instances where these PD measurements have been useful for identifying stator bars or coils which may have short times to failure on voltage endurance. This paper updates the evidence.
Keywords :
bars; coils; partial discharge measurement; stators; coils; measured partial discharge; partial discharge screening tests; stator bars; Bars; Coils; Partial discharge measurement; Partial discharges; Stator bars; Voltage measurement; Windings; partial discharge; rotating machines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference (EIC), 2011
Conference_Location :
Annapolis, MD
ISSN :
pending
Print_ISBN :
978-1-4577-0278-5
Electronic_ISBN :
pending
Type :
conf
DOI :
10.1109/EIC.2011.5996107
Filename :
5996107
Link To Document :
بازگشت