• DocumentCode
    55773
  • Title

    Energy savings on frequency regulation of ship´s cooling circuits

  • Author

    Chien-Hsing Lee ; Shih-Hsien Hsu ; Chien-Nan Chen ; Ming-Yuan Cho ; Foung-Tang Lin ; Tzu-Kuei Yeh ; Zhi-Wei Liu

  • Author_Institution
    Dept. of Syst. & Naval Mechatron. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
  • Volume
    50
  • Issue
    3
  • fYear
    2014
  • fDate
    Jul-14
  • Firstpage
    1813
  • Lastpage
    1825
  • Abstract
    To calculate potential energy savings in a ship´s cooling circuits, a simulation model of frequency-controlled seawater (SW) pumps is proposed that has been verified by measurements. The pumps operating at a minimum frequency of 30 Hz have a maximum energy reduction of almost 79% under both full and part load conditions when the SWintake is below 32°C. A return-on-investment period of only a few months is calculated for the frequency-controlled drive on a container vessel.
  • Keywords
    containers; drives; frequency control; investment; pumps; seawater; ships; container vessel; frequency 30 Hz; frequency regulation; frequency-controlled SW pumps; frequency-controlled drive; frequency-controlled seawater pumps; maximum energy reduction; potential energy savings; return-on-investment period; ship cooling circuits; simulation model; Cooling; Energy management; Heat transfer; Heating; Integrated circuit modeling; Marine vehicles;
  • fLanguage
    English
  • Journal_Title
    Aerospace and Electronic Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9251
  • Type

    jour

  • DOI
    10.1109/TAES.2014.130354
  • Filename
    6965741