• DocumentCode
    56326
  • Title

    Insulation characteristics of GIS epoxy insulators with non-uniform surface resistance under DC voltage

  • Author

    Okabe, Shigemitsu ; Ueta, Genyo ; Nojima, Kenichi

  • Author_Institution
    Tokyo Electr. Power Co., Yokohama, Japan
  • Volume
    22
  • Issue
    1
  • fYear
    2015
  • fDate
    Feb. 2015
  • Firstpage
    516
  • Lastpage
    525
  • Abstract
    Now that gas-insulated switchgear (GIS) for ac systems are becoming increasingly compact as specifications are rationalized, more consideration of their insulation characteristics for residual dc voltage is required. Furthermore, with dc power transmission technology drawing more and more global attention, clarifying the insulation characteristics of GIS for dc voltage is increasingly important. For GIS insulating epoxy spacer, the present paper experimentally and analytically studied the influence of spacer surface condition on dc withstand voltage performance. In specific terms, initially, an insulating spacer model with an area of non-uniform resistivity present in the surface layer was created and the dc voltage breakdown characteristics were obtained. As a result, it was clarified that the time delay to breakdown increased with lowering the applied voltage, or in other words, even if a low voltage was applied, breakdown may occur after an extended period. Subsequently, using the same non-uniform resistivity model, the change in the electric field distribution over time under dc voltage was investigated through transient electric field analysis. Consequently, it was found that the electric field distribution varied from a capacitive to a resistive field and the maximum electric field was generated in the boundary between the high- and low-resistivity areas. It was further clarified, based on these breakdown characteristics and electric field analytical results, that the presence of an area of nonuniform resistivity on the insulating spacer creepage surface caused electric field concentration over time and breakdown occurred if the electric field in the creepage surface direction exceeded 40 kV/mm or so. Moreover, the breakdown characteristics were investigated where a lightning impulse voltage was superimposed over a dc voltage. Consequently, the creepage breakdown electric field where a dc voltage was applied alone was almost identical to that where the superi- posed voltage was applied. It means that the application of the superimposed voltage may potentially allow the insulating spacer withstand voltage performance to be evaluated by a shorter time test for a dc voltage alone or the dc voltage with a superimposed VFTO.
  • Keywords
    DC power transmission; electric breakdown; electric fields; epoxy insulators; gas insulated switchgear; GIS epoxy insulators; VFTO; ac systems; creepage surface direction; dc power transmission technology; dc voltage breakdown characteristics; gas-insulated switchgear; high-resistivity areas; insulating epoxy spacer; insulation characteristics; lightning impulse voltage; low-resistivity areas; nonuniform resistivity model; nonuniform surface resistance; residual dc voltage; spacer surface condition; superimposed voltage; surface layer; time delay; transient electric field analysis; Analytical models; Breakdown voltage; Conductivity; Electric breakdown; Electric fields; Insulation; Resins; Gas insulated switchgear (GIS); SF6 gas; dc voltage; epoxy insulator; insulation characteristic; lightning impulse voltage test; surface resistance; transient electric field analysis;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2014.004513
  • Filename
    7033424