DocumentCode
563265
Title
Vircator experiments on repetitive pulsed power generator “ETIGO-IV”
Author
Jiang, Weihua ; Sato, Masaki ; Yatsui, Kiyoshi
Author_Institution
Extreme Energy-Density Research Institute, Nagaoka University of Technology, Niigata 940-2188, Japan
Volume
1
fYear
2002
fDate
23-28 June 2002
Firstpage
315
Lastpage
318
Abstract
A new configuration of virtual cathode oscillator is proposed and tested experimentally. A resonant cavity is used to enhance the field feedback to the virtual cathode oscillation. The experiments were carried out on repetitive pulsed power generator “ETIGO-IV” (400 kV, 13 kA, 120 ns, 1 Hz). The diagnostic results have shown the peak microwave output power of ∼ 450 MW, giving peak-to-peak microwave power efficiency of ∼ 9 %.