DocumentCode
569914
Title
Thermal simulation of small capacity AC contactor based on ANSYS
Author
Liu Guojin ; Liu Haiqiang ; Zheng Bin
Author_Institution
Province-Minist. Joint Key Lab. of Electromagn. Field & Electr. Apparatus Reliability, Hebei Univ. of Technol., Tianjin, China
fYear
2012
fDate
14-17 May 2012
Firstpage
479
Lastpage
483
Abstract
Based on ANSYS, the thermal analysis on the small capacity AC contactor is put forward in this paper. After the model of contactor with 9A rated current is established, the temperature field of the contactor is simulated considering the heating and heat-dissipating calculation. The heating calculation includes the heating of electrical-magnetic system and the resistances of circuit and contact. The heat-dissipation calculation includes the inner conduction, the convection and radiation of surfaces.
Keywords
contactors; convection; cooling; electromagnets; thermal analysis; vacuum contactors; AC contactor; ANSYS; electromagnet system; heat convection; heat dissipation; heating calculation; temperature field; thermal analysis; thermal simulation; AC contactor; ANSYS; temperature field; thermalelectric coupling;