• DocumentCode
    588013
  • Title

    Proto-I axial focusing experiments

  • Author

    Johnson, D. J. ; Leeper, R. J. ; Stygar, W. A. ; Slutz, S. A.

  • Author_Institution
    Sandia National Laboratories, Albuquerque, NM 87185, USA
  • fYear
    1983
  • fDate
    12-14 Sept. 1983
  • Firstpage
    89
  • Lastpage
    92
  • Abstract
    The time-integrated axial (z) focus of the 4.5cm-radius Proto I (1.5 MV, 500 kA) radial proton diode is presently limited to ∼3 mm FWHM. This result is obtained with current neutralized beam transport in a gas cell with 6 Torr argon. If the vertical local divergence were the same (1° or less) as the horizotal divergence, the local divergence alone would produce a 1.5 mm FWHM focus. The axial focal size is evidently limited by time-dependent effects. These are studied by observing the beam incident upon various targets with two time-resolved pinhole cameras. The first camera observes Rutherford-scattered protons from gold targets with an array of 11 silicon PIN detectors. The second camera observes Kα-florescence from aluminum targets with 4 independently-gated microchannel plates imaging tubes.
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High-Power Particle Beams, 1983. HPPB. 5th International Conference on
  • Conference_Location
    San Francisco, CA, USA
  • Type

    conf

  • Filename
    6403786