• DocumentCode
    58945
  • Title

    Study of the Copper Losses in a High-Speed Permanent-Magnet Machine With Form-Wound Windings

  • Author

    Gonzalez, Delvis A. ; Saban, Daniel M.

  • Author_Institution
    Danfoss Turbocor Compressors, Tallahassee, FL, USA
  • Volume
    61
  • Issue
    6
  • fYear
    2014
  • fDate
    Jun-14
  • Firstpage
    3038
  • Lastpage
    3045
  • Abstract
    This paper investigates the profile of the copper losses in a 5.0-MW high-speed permanent-magnet machine with form-wound winding. The machine was tested, and the test data were used in conjunction with the results obtained from finite-element simulations to calculate the copper losses over the complete speed range. A retardation test in open-circuit conditions was performed to calculate the eddy current loss induced inside the stator coils by the rotor magnetic flux. The results demonstrate that this component of the copper losses is significantly high in form-wound machines at high-speed operation. The impact of the slot configuration on the proximity effect was also investigated. Open and semiclosed slots were compared, and the study results show that the high flux concentration in the slot opening region associated with semiclosed slots increases the proximity copper loss compared with the open-slot topology. At the end, this paper proposes the stator-alone test as a valid method to calculate resistance per phase at high frequency and estimates its increment over the direct current resistance.
  • Keywords
    coils; eddy current losses; finite element analysis; machine testing; magnetic flux; permanent magnet machines; stators; copper loss calculation; direct current resistance; eddy current loss calculation; finite-element simulation; form-wound winding; high-speed permanent-magnet machine; machine testing; open-circuit condition; open-slot topology configuration; power 5.0 MW; proximity effect; retardation testing; rotor magnetic flux; semiclosed slot configuration; stator coil; stator-alone testing; AC copper losses; high-speed electric machines; permanent-magnet (PM) machine; skin and proximity effects;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2013.2262759
  • Filename
    6515614