DocumentCode
589966
Title
Effect study of spectrum analyzer noise floor on antenna noise temperature measurement
Author
Zhen-Dong Wu ; Shun-You Qin
Author_Institution
Fifty Fourth Inst. of CETC, Shijiazhuang, China
fYear
2012
fDate
22-26 Oct. 2012
Firstpage
8
Lastpage
10
Abstract
In this paper, Y-factor method of measuring antenna noise temperature is described simply using spectrum analyzer. Effect of spectrum analyzer noise floor on noise power measurement is analyzed. Calculation formula and numerical value curve of correction factor are given. Calculation of correction Y-factor is described. At fast, measuring results of C-band 13-metre vehicle antenna noise temperature are given. Test result show that effect of spectrum analyzer noise floor on antenna noise measurement is not neglected when ratio of spectrum analyzer measuring noise power to noise floor power is less than 20dB.
Keywords
antenna testing; electric noise measurement; spectral analysers; antenna noise temperature measurement; correction Y-factor method; noise power measurement; numerical value curve; size 13 m; spectrum analyzer noise floor; vehicle antenna noise temperature; Antenna measurements; Floors; Noise; Noise measurement; Power measurement; Temperature; Temperature measurement; Antenna noise temperature measurement; Correction factor; Y-factor method;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas, Propagation & EM Theory (ISAPE), 2012 10th International Symposium on
Conference_Location
Xian
Print_ISBN
978-1-4673-1799-3
Type
conf
DOI
10.1109/ISAPE.2012.6408688
Filename
6408688
Link To Document