Comparative study on the calculation of nitrogen oxide emissions
Author :
Staviri, V.-F. ; Eduard, G.
Author_Institution :
Dept. of Power Eng., Gheorghe Asachi Tech. Univ. of Iasi, Iasi, Romania
fYear :
2012
fDate :
25-27 Oct. 2012
Firstpage :
990
Lastpage :
993
Abstract :
The objective of this work is to determine the amount of nitrogen oxides per hour in a period of one year of the CRG 1870, 420 t/h boiler. In the second phase of paper was carried out a comparative study of nitrogen oxide emissions caused by the methodology used by SC CET SA Bacau, based on CORINAIR emission factors, and the mathematical model obtained on the flow due time.
Keywords :
air pollution measurement; boilers; nitrogen; CORINAIR emission factors; SC CET SA Bacau; flow; mathematical model; nitrogen oxide emissions; steam boiler; Atmosphere; Boilers; Coal; Mathematical model; Nitrogen; Turbines; emission factors; nitrogen oxides; steam boiler;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Power Engineering (EPE), 2012 International Conference and Exposition on
Conference_Location :
Iasi
Print_ISBN :
978-1-4673-1173-1
Type :
conf
DOI :
10.1109/ICEPE.2012.6463804
Filename :
6463804
Link To Document :