• DocumentCode
    599571
  • Title

    RADFET dosimeter design for environment monitoring applications

  • Author

    Meguellati, M. ; Djeffal, F. ; Arar, D. ; Bendib, T. ; Khettache, L.

  • Author_Institution
    LEA, Department of Electronics, University of Batna, 05000, Algeria
  • fYear
    2012
  • fDate
    16-20 Dec. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this paper, a radiation sensitive FET (RADFET) dosimeter design (called the Dual-Dielectric Gate All Around DDGAA RADFET dosimeter) to improve the radiation sensitivity performance and its analytical analysis have been proposed for RADFET dosimeter-based applications (monitoring, robotics, medical sciences,…). The proposed device has been implemented in SIMULINK tool to show the impact of the proposed dosimeter on the environment monitoring applications. The obtained results make the DDGAA RADFET dosimeter a promising candidate for environment monitoring applications.
  • Keywords
    Genetic Algorithm; RADFET; dosimeter; irradiation; sensitivity; traps;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microelectronics (ICM), 2012 24th International Conference on
  • Conference_Location
    Algiers, Algeria
  • Print_ISBN
    978-1-4673-5289-5
  • Type

    conf

  • DOI
    10.1109/ICM.2012.6471435
  • Filename
    6471435