DocumentCode :
60584
Title :
Timing and Energy Resolution of New Near-UV SiPMs Coupled to {\\rm LaBr}_3 :Ce for TOF-PET
Author :
Schmall, Jeffrey P. ; Wiener, Rony I. ; Surti, Suleman ; Ferri, Alessandro ; Gola, Alberto ; Tarolli, Alessandro ; Piemonte, C. ; Karp, Joel S.
Author_Institution :
Univ. of Pennsylvania, Philadelphia, PA, USA
Volume :
61
Issue :
5
fYear :
2014
fDate :
Oct. 2014
Firstpage :
2426
Lastpage :
2432
Abstract :
The high light output and fast decay time of LaBr3:Ce scintillation detectors leads to excellent timing performance. To realize the potential of timing resolution with LaBr3:Ce we have investigated the performance with SiPMs, which enable 1-to-1 coupling to individual crystals, and which have been optimized for the near-ultraviolet (NUV) scintillation light emission of LaBr3:Ce. Coincidence timing resolution (CTR) of 100 ps was measured for a 4 ×4 ×5 mm3 LaBr3:30%Ce crystal directly coupled to a large-area 4 ×4 mm2 NUV-SiPM. Results show very little dependence on temperature, in the range of - 20° to 20°C, and bias voltage, from 2 V to 5 V over breakdown. Optimal performance was achieved at an over-voltage (OV) range of 3 V - 5 V, at which high gain and high photon detection efficiency are achieved. Though saturation was evident at 511 keV, an energy resolution of 6.8% was measured after correcting for non-linearity. We also measured a CTR of 110 ps for a 4 ×4 ×5 mm3 LaBr3:5%Ce crystal and 245 ps for a 4 ×4 ×30 mm3 LaBr3:5%Ce crystal using the NUV-SIPM. The poorer timing measurement for the 30-mm long crystal is due mainly to a systematic shift in the time pick-off as a function of the depth-of-interaction. The excellent temperature stability, fast rise time, high gain, and low noise of the NUV-SiPM make it a practical and highly appealing photodetector for the readout of a LaBr3:Ce TOF-PET detector.
Keywords :
coincidence techniques; nuclear electronics; photomultipliers; positron emission tomography; readout electronics; silicon radiation detectors; solid scintillation detectors; LaBr3:Ce TOF-PET scintillation detector; bias voltage; coincidence timing resolution; depth-of-interaction function; detector readout; near-UV SiPM energy resolution; near-ultraviolet scintillation light emission; photodetector; photon detection efficiency; temperature stability; Crystals; Detectors; Energy resolution; Photonics; Positron emission tomography; Temperature measurement; Timing; Coincidence timing resolution; Lanthanum Bromide; PET; silicon photomultiplier; time-of-flight PET;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2014.2346579
Filename :
6894247
Link To Document :
بازگشت