• DocumentCode
    608402
  • Title

    Modified Gardner phase detector for Nyquist coherent optical transmission systems

  • Author

    Stojanovic, N. ; Changsong Xie ; Yu Zhao ; Bangning Mao ; Gonzalez, Neil ; Juan Qi ; Le Nguyen Binh

  • Author_Institution
    Eur. Res. Center, Huawei Technol. Duesseldorf GmbH, Munich, Germany
  • fYear
    2013
  • fDate
    17-21 March 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    We present a novel timing recovery scheme based on a Gardner phase detector performing excellently in spectrally efficient Nyquist coherent optical systems. Good clock tone performance is obtained for QAM modulation formats and roll-off factor (ROF) values close to 0.
  • Keywords
    optical fibre networks; phase detectors; quadrature amplitude modulation; Nyquist coherent optical transmission systems; QAM modulation; ROF values; modified Gardner phase detector; roll-off factor; timing recovery scheme; Clocks; Detectors; Finite impulse response filters; Modulation; Nonlinear optics; Optical filters; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Optical Fiber Communication Conference and Exposition and the National Fiber Optic Engineers Conference (OFC/NFOEC), 2013
  • Conference_Location
    Anaheim, CA
  • Print_ISBN
    978-1-4799-0457-0
  • Type

    conf

  • Filename
    6532542