Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo
Author
Samiotaki, Gesthimani ; Konofagou, Elisa
Author_Institution
Dept. of Radiol., Columbia Univ., New York, NY, USA
Volume
60
Issue
11
fYear
2013
fDate
Nov-13
Firstpage
2257
Lastpage
2265
Abstract
The most challenging aspect of intravenously-administered drugs currently developed to treat central nervous system (CNS) diseases is their impermeability through the blood-brain barrier (BBB), a specialized vasculature system protecting the brain microenvironment. Focused ultrasound (FUS) in conjunction with systemically administered microbubbles has been shown to open the BBB locally, noninvasively, and reversibly. The objective of this study was to investigate the effect of FUS (center frequency: 1.5 MHz) pulse length (PL), ranging here from 67 μs to 6.7 ms, on the physiology of the FUS-induced BBB opening. Dynamic contrastenhanced (DCE) and T1-weighted magnetic resonance imaging (MRI) were used to quantify the permeability changes using transfer rate (Ktrans) mapping, the volume of BBB opening (VBBB) and the reversibility timeline of the FUS-induced BBB opening, with the systemic administration of microbubbles at different acoustic pressures, ranging from 0.30 to 0.60 MPa. Permeability and volume of opening were both found to increase with the acoustic pressure and pulse length. At 67-μs PL, the opening pressure threshold was 0.45 MPa, with BBB opening characteristics similar to those induced with 0.60 MPa at the same PL, as well as with 0.67-ms PL/0.30 MPa. On average, these cases had Ktrans = 0.0049 ± 0.0014 min-1 and VBBB = 3.7 ± 4.3 mm3, and closing occurred within 8 h. The 6.7-ms PL/0.30 MPa induced similar opening with 0.67-ms PL/0.45 MPa, and a closing timeline of 24 to 48 h. On average, Ktrans was 0.0091 ± 0.0029 min-1 and VBBB was 14.13 ± 7.7 mm3 in these cases. Also, there were no significant differences between the 6.7-ms PL/0.45 MPa, 0.67-ms PL/0.60 MPa and 6.7-ms PL/0.60 MPa cases, yielding on average a Ktrans of 0.0100 ± 0.0023 min-1 and VBBB equal to 20.1 ± 5.7 mm3. Closing occurred wit- in 48 to 72 h in these cases. Stacked histograms of the Ktrans provided further insight to the nonuniform spatial distribution of permeability changes and revealed a correlation with the closing timeline. These results also suggest a beneficial complementary relationship between the elongation of the PL and the decrease of the peak negative acoustic pressures, and vice versa. Linear regression between Ktrans and VBBB showed a good correlation fit. Also, the time required for closing linearly increased with VBBB. The volume rate of decrease was measured to be 11.4 ± 4.0 mm3 per day, suggesting that the closing timeline could be predicted from the initial volume of opening. Finally, no histological damage was detected in any of the cases 7 d post-FUS, indicating the safety of the methodology and parameters used.
Keywords
biomedical MRI; biomedical ultrasonics; blood; brain; bubbles; diseases; drugs; neurophysiology; permeability; regression analysis; FUS-induced BBB opening; MRI; T1-weighted magnetic resonance imaging; acoustic pressures; brain microenvironment; central nervous system diseases; elongation; focused-ultrasound-induced blood-brain barrier opening; histological damage; intravenously-administered drugs; linear regression; microbubbles; permeability; physiology; specialized vasculature system; transfer rate mapping; Acoustics; Magnetic resonance imaging; Mice; Permeability; Transducers; Ultrasonic imaging; Volume measurement; Animals; Blood-Brain Barrier; Drug Delivery Systems; Hippocampus; Magnetic Resonance Imaging; Male; Mice; Mice, Inbred C57BL; Microbubbles; Ultrasonic Therapy;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2013.6644731
Filename
6644731
Link To Document