DocumentCode
62386
Title
Loss minimisation in λ/4 impedance transformers using multiple lλ4 segments
Author
Li, Cong ; Ricketts, David S.
Author_Institution
ECE, Carnegie Mellon Univ., Pittsburgh, PA, USA
Volume
49
Issue
4
fYear
2013
fDate
Feb. 14 2013
Firstpage
274
Lastpage
276
Abstract
Presented is an analysis of loss in quarter-wavelength impedance transformers. It is shown that the loss of an impedance transformer, S21, is a function not only of the dielectric and conductor loss, but also the transformation ratio. S21 is derived as a function of both loss and transformation ratio and it is shown that for high transformation ratios, using two or even three quarter-wavelength impedance transformers results in an overall lower loss.
Keywords
dielectric losses; transformers; transmission lines; λ/4 impedance transformer; conductor loss; dielectric loss; loss minimisation; multiple λ/4 segment; quarter-wavelength impedance transformer;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el.2012.3382
Filename
6464683
Link To Document