Title :
Modernization and calibration of intrferometer of TOKAMAK “Compass”
Author :
Varavin, M. ; Zajac, Jozef ; Zacek, F. ; Nanobashvili, S. ; Ermak, G. ; Varavin, A. ; Vasilev, Andrey ; Stumbra, M. ; Vetoshko, A. ; Fateev, A. ; Shevchenko, Valentin
Author_Institution :
Assoc. EURAATOM/IPP.CR, Inst. of Plasma Phys., Prague, Czech Republic
Abstract :
This article presents “Compass” TOKAMAK microwave diagnostics calibration and results accuracy enhancing experiment methodology. Main subject is microwave diagnostic system phase measurements description. Additional interest is mistakes, attendant to phase measurement. Emphasis is put on phase detectors measurements mistakes correction methodology; two different phase meter configurations are described. Phase detectors, based on AD8302 CPLD, results processing methodology are presented.
Keywords :
Tokamak devices; calibration; phase detectors; phase measurement; phase meters; plasma diagnostics; radiowave interferometers; AD8302 CPLD; TOKAMAK compass; TOKAMAK microwave diagnostics calibration; accuracy enhancing experiment methodology; interferometer; microwave diagnostic system phase measurements description; modernization; phase detectors measurements mistakes correction methodology; phase meter configurations; Detectors; Frequency measurement; Phase measurement; Plasma density; Plasma measurements; Tokamaks;
Conference_Titel :
Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves (MSMW), 2013 International Kharkov Symposium on
Conference_Location :
Kharkiv
Print_ISBN :
978-1-4799-1066-3
DOI :
10.1109/MSMW.2013.6622126