DocumentCode
64343
Title
Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters
Author
Pena-Alzola, Rafael ; Liserre, Marco ; Blaabjerg, Frede ; Sebastian, Rafael ; Dannehl, Jorg ; Fuchs, Friedrich Wilhelm
Author_Institution
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
Volume
10
Issue
1
fYear
2014
fDate
Feb. 2014
Firstpage
43
Lastpage
52
Abstract
Three-phase active rectifiers guarantee sinusoidal input currents and unity power factor at the price of a high switching frequency ripple. To adopt an LCL-filter, instead of an L-filter, allows using reduced values for the inductances and so preserving dynamics. However, stability problems can arise in the current control loop if the present resonance is not properly damped. Passive damping simply adds resistors in series with the LCL-filter capacitors. This simplicity is at the expense of increased losses and encumbrances. Active damping modifies the control algorithm to attain stability without using dissipative elements but, sometimes, needing additional sensors. This solution has been addressed in many publications. The lead-lag network method is one of the first reported procedures and continues being in use. However, neither there is a direct tuning procedure (without trial and error) nor its rationale has been explained. Thus, in this paper a straightforward procedure is developed to tune the lead-lag network with the help of software tools. The rationale of this procedure, based on the capacitor current feedback, is elucidated. Stability is studied by means of the root locus analysis in z-plane. Selecting the lead-lag network for the maximum damping in the closed-loop poles uses a simple optimization algorithm. The robustness against the grid inductance variation is also analyzed. Simulations and experiments confirm the validity of the proposed design flow.
Keywords
damping; electric current control; optimisation; power convertors; power factor; power grids; rectifiers; LCL-filter capacitors; active damping; current control loop; frequency ripple; grid inductance; lead-lag network; passive damping; power factor; root locus analysis; simple optimization algorithm; software tools; three phase converters; three-phase active rectifiers; Active damping; LCL-filter; lead-lag; rectifier; stability; voltage-source converter;
fLanguage
English
Journal_Title
Industrial Informatics, IEEE Transactions on
Publisher
ieee
ISSN
1551-3203
Type
jour
DOI
10.1109/TII.2013.2263506
Filename
6516904
Link To Document