DocumentCode
644716
Title
Broadband orthomode transducer for the WR12-band
Author
Cenanovic, Amir ; Koppel, T. ; Ringel, Julia ; Schmidt, Lorenz-Peter
Author_Institution
Inst. of Microwaves & Photonics (LHFT), Friedrich-Alexander Univ. of Erlangen-Nuremberg, Nuremberg, Germany
fYear
2013
fDate
1-6 Sept. 2013
Firstpage
1
Lastpage
2
Abstract
In this work a broadband waveguide orthomode transducer (OMT) operating at the entire WR12 band is presented. The compact size OMT is fabricated in split-block technique. It exhibits an insertion loss below 0.6 dB and return loss values for the horizontal polarization greater than 20 dB and for the vertical polarization greater than 17 dB at 69 - 90 GHz. The simulated isolation between the orthogonal polarization ports is better than - 65 dB across the 60 - 90 GHz band.
Keywords
microwave circulators; transducers; waveguide components; OMT; WR12-band; broadband orthomode transducer; broadband waveguide orthomode transducer; frequency 69 GHz to 90 GHz; horizontal polarization; split-block technique; vertical polarization; Antenna measurements; Broadband antennas; Dielectric measurement; Insertion loss; Loss measurement; Ports (Computers); Transducers;
fLanguage
English