  • Abstract
    A broadband rectangular waveguide calorimeter is fabricated to establish a reliable mm-wave power standard in the frequency range from 110 GHz to 170 GHz. Two types of mm-wave power meter are calibrated using this calorimeter and their calibration factors are reported with their uncertainties. Uncertainty calculations are based on the Monte Carlo method.
  • Keywords
    Monte Carlo methods; calibration; calorimeters; measurement uncertainty; microwave measurement; power meters; rectangular waveguides; Monte Carlo method; broadband calorimeter; broadband rectangular waveguide calorimeter; frequency 110 GHz to 170 GHz; millimeter wave power meter calibration; millimeter wave power standard; uncertainty calculation; Broadband communication; Calibration; Frequency measurement; Power measurement; Time measurement; Transmission line measurements; Uncertainty;