• DocumentCode
    657252
  • Title

    Parametric amplification in a micro Coriolis mass flow sensor: Reduction of power dissipation without loss of sensitivity

  • Author

    Groenesteijn, J. ; Droogendijk, H. ; Wiegerink, R.J. ; Lammerink, T.S.J. ; Lotters, J.C. ; Sanders, R.G.P. ; Krijnen, G.J.M.

  • Author_Institution
    MESA Inst. for Nanotechnol., Univ. of Twente, Enschede, Netherlands
  • fYear
    2013
  • fDate
    3-6 Nov. 2013
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    We report on the application of parametric amplification to a micro Coriolis mass flow sensor to reduce the system´s power dissipation while retaining sensitivity to flow. By reducing this power dissipation, less heat will be transferred to the fluid and channel, potentially resulting in more temperature-stable flow measurements. We show experimentally that parametric amplification can be used to either greatly reduce power dissipation without loss of flow sensitivity, or to increase the overall sensitivity without increased power dissipation.
  • Keywords
    amplification; flow sensors; microfluidics; microsensors; microCoriolis mass flow sensor; parametric amplification; power dissipation reduction; temperature stable flow measurement; Current measurement; Displacement measurement; Electron tubes; Heating; Power dissipation; Sensitivity; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SENSORS, 2013 IEEE
  • Conference_Location
    Baltimore, MD
  • ISSN
    1930-0395
  • Type

    conf

  • DOI
    10.1109/ICSENS.2013.6688538
  • Filename
    6688538