DocumentCode
66109
Title
Characteristics of Upward Positive Lightning Initiated From the Peissenberg Tower, Germany
Author
Heidler, Fridolin H. ; Manhardt, Michael ; Stimper, Klaus
Author_Institution
Dept. of Electr. & Comput. Eng., Univ. of the Fed. Armed Forces Munich, Neubiberg, Germany
Volume
57
Issue
1
fYear
2015
fDate
Feb. 2015
Firstpage
102
Lastpage
111
Abstract
Subject matter of this paper is the analysis of the total of six upward positive lightning initiated from the Peissenberg Tower, Germany. All of them occurred during the cold season from February to April in the years 1997 to 1999. Three of them were initiated without nearby preceding lightning activity (called “self-initiated” upward lightning) and the other three occurred during nearby lightning activity (called “other-triggered” upward lightning). The analysis suggests that the other-triggered upward lightning is a downward lightning involving a relatively long upward connecting leader. The first current component, however, was different from the current of a first return stroke of a positive cloud-to-ground flash. On average, the duration was 15.7 ms, the maximum was 4.37 kA, and the charge was 13.3 C. Due to the long duration and the relatively low current, the first current component is more consistent with the initial continuous current (ICC) of an upward lightning. The initial period of the ICC exhibits a slowly rising portion lasting about 1 ms. During that period, the ICC was superimposed by weak current pulses. The arithmetic means of the pulse peak and the pulse duration were 0.49 kA and 9.6 μs, respectively. The average leader velocity was 2.3 × 105 m/s and the average leader charge density was 1.02 × 10-3 C/m. Much stronger current pulses were observed after that initial period. Then, the arithmetic means were 5.3 kA for the pulse peak and 46.6 μs for the pulse duration. The ICC of the self-initiated upward lightning did not exhibit such an initial slowly rising portion with weak superimposed current pulses. The ICC immediately increased to several kilo-amperes involving strong current pulsation. For the ICC, the arithmetic means were 58 ms for the duration, 6.4 kA for the maximum, and 105 C for the charge. For the current pulses, the arithmetic means were 5.7 kA for- the pulse peak and 19 μs for the pulse duration. The leader charge density was estimated to be up to several 10 mC/m.
Keywords
electric charge; lightning protection; Germany; Peissenberg Tower; charge density; current 4.37 kA; downward lightning; initial continuous current; positive cloud-to-ground flash; self-initiated upward lightning ICC; strong current pulsation; time 15.7 ms; upward positive lightning characteristics; Antenna measurements; Ash; Current measurement; Joining processes; Lightning; Poles and towers; Sea measurements; Lightning currents; lightning electric field; positive lightning; upward leader; upward lightning;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.2014.2359584
Filename
6971147
Link To Document