DocumentCode :
662128
Title :
Reliable estimation of respiration rate using UWB impulse radar
Author :
Jae-Mo Kang ; Dong-Woo Lim ; Jae-Hwan Lee ; Changdon In ; Hyung-Myung Kim ; Sung-Chul Woo ; Cheonsoo Kim
Author_Institution :
Dept. of Electr. Eng., Korea Adv. Inst. of Sci. & Technol., Daejeon, South Korea
fYear :
2013
fDate :
5-8 Nov. 2013
Firstpage :
997
Lastpage :
999
Abstract :
In this paper, we present a procedure for reliable estimation of the respiration rate using UWB impulse radar. We initially extract the respiratory signal using the energy detector to reduce the effect of the multipath impulse response of the human body. Then, the noise subspace methods are applied to estimate the respiration-rate more accurately. The experimental results show that the proposed method is more reliable than the conventional method.
Keywords :
biomedical communication; telecommunication network reliability; transient response; ultra wideband radar; UWB impulse radar; energy detector; multipath impulse response; noise subspace methods; reliable estimation; respiration rate; respiratory signal; ultrawideband impulse radar; Correlation; Detectors; Estimation; Frequency estimation; Noise; Reliability; Ultra wideband radar; UWB impulse radar; energy detector; high range resolution; noise subspace method; respiration-rate;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference Proceedings (APMC), 2013 Asia-Pacific
Conference_Location :
Seoul
Type :
conf
DOI :
10.1109/APMC.2013.6695002
Filename :
6695002
Link To Document :
بازگشت