Abstract
Dose dependence of radiation-induced optical attenuation (RIA) at 1310 nm of the Co/Fe co-doped alumino-silicate optical fiber was investigated under gamma-ray irradiation at dose rates from 6.7 to 78.3 Gy/min. From the measured RIA, radiation dose sensitivity (ΔRIA/ΔDose) and rate of RIA change with irradiation time (ΔRIA/ΔTime) at the different dose rates were estimated. RIAs at various wavelengths (800 to 1600 nm) of the optical fiber were also measured and the RIA characteristics at 800 and 1310 nm under discrete gamma-ray irradiation were investigated. The measured RIA of the Co/Fe co-doped fiber showed very high dose sensitivity regardless of the dose rates and the ΔRIA/ΔTime was found to show linear response with respect to the dose rate. The significantly large RIA was attributed to Co, Fe, and Al-related defects in the fiber core which were formed by the irradiation, and it became larger at shorter wavelength. The high radiation dose sensitivity, linear response of the ΔRIA/ΔTime with respect to dose rate, and the high reproducibility of the dose dependence of RIA under the discrete irradiation clearly indicate that the Co/Fe co-doped fiber is able to provide highly accurate information of not only total accumulated dose but also dose rate of the radiation with irradiation time.
Keywords
aluminium compounds; cobalt; dosimeters; fibre optic sensors; gamma-ray effects; iron; optical fibre testing; Al2O3-SiO2:Co,Fe; codoped alumino-silicate optical fiber; dose dependence; dosimeter application; gamma-ray irradiation-induced optical attenuation; irradiation time; radiation dose rate; radiation dose sensitivity; wavelength 800 nm to 1600 nm; Absorption; Gamma-rays; Iron; Optical fibers; Optical variables measurement; Radiation effects; Sensitivity; Defect center; dosimetry; fiber optic sensor; gamma-ray; optical fiber dosimeter; radiation-induced attenuation;
fLanguage
English
Journal_Title
Lightwave Technology, Journal of
Publisher
ieee
ISSN
0733-8724
Type
jour
DOI
10.1109/JLT.2014.2357798
Filename
6897917
Link To Document