• DocumentCode
    666349
  • Title

    Development of non-pulsatile tube pump

  • Author

    Katoh, Kentaroh ; Kawaguchi, A. ; Uya, Kazuki ; Nishikori, Makoto

  • Author_Institution
    Dept. of Control Eng., Matsue Coll. of Technol., Matsue, Japan
  • fYear
    2013
  • fDate
    10-13 Nov. 2013
  • Firstpage
    4103
  • Lastpage
    4108
  • Abstract
    Tube pumps have been used in many applications for cleanliness and convenience. It is basically constructed by some rollers which rotate and transfer the fluid in the tube by pressing it down from the outside. However, it is known that the flow pulsation occurs when the roller removes from the tube in relation to the tube recovery. Therefore, we developed a new tube pump which consists of pantographs and a grooved cam. The mechanism, the design method, the mechanical analysis and the advantage of the pump are described with some simulation and experimental results.
  • Keywords
    cams (mechanical); pantographs; product design; product development; pumps; design; flow pulsation; grooved cam; nonpulsatile tube pump development; pantographs; rollers; tube recovery; Design methodology; Electron tubes; Force; Numerical simulation; Shafts; Torque; Vectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics Society, IECON 2013 - 39th Annual Conference of the IEEE
  • Conference_Location
    Vienna
  • ISSN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2013.6699793
  • Filename
    6699793