• DocumentCode
    668235
  • Title

    Comparative analysis of high-gain observers applied to a distillation column

  • Author

    Heras-Cervantes, M. ; Tellez-Anguiano, A.C. ; Garcia Ramirez, M.C. ; Gutierrez-Gnecchi, J.A. ; Fernandez-Munoz, O. ; Olivares-Peregrino, V.H.

  • Author_Institution
    Electron. Dept., Inst. Tecnol. de Morelia, Morelia, Mexico
  • fYear
    2013
  • fDate
    13-15 Nov. 2013
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper presents a comparative analysis of two types of high-gain observers used to estimate the molar compositions in a distillation column for a binary mixture (Ethanol-Water) using the temperature measurements in the plates. These observers are selected according to the system characteristics: triangular structure, locally Lipchitz and bounded states. The aim is to select the high-gain observer best suited to develop efficient fault detection systems to help prevent accidents and improve the safety of the user and the process, maintaining a balance between reliability, efficiency and ease of implementation.
  • Keywords
    accident prevention; distillation equipment; fault diagnosis; mixtures; observers; reliability; temperature measurement; accident prevention; binary mixtures; bounded states; distillation column; ethanol-water mixtures; fault detection; high-gain observers; locally Lipchitz states; molar composition estimation; reliability; safety; temperature measurement; Boilers; Distillation equipment; Liquids; Mathematical model; Observers; Technological innovation; Temperature measurement; Distillation column; FDI; high-gain observers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power, Electronics and Computing (ROPEC), 2013 IEEE International Autumn Meeting on
  • Conference_Location
    Mexico City
  • Type

    conf

  • DOI
    10.1109/ROPEC.2013.6702743
  • Filename
    6702743