• DocumentCode
    67171
  • Title

    General SVPWM strategy for three different four-switch three-phase inverters

  • Author

    Yong-Chao Liu ; Xing-Lai Ge ; Jie Zhang ; Xiao-Yun Feng

  • Author_Institution
    Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
  • Volume
    51
  • Issue
    4
  • fYear
    2015
  • fDate
    2 19 2015
  • Firstpage
    357
  • Lastpage
    359
  • Abstract
    Four-switch three-phase inverters (FSTPIs) are post-fault reconfigured topologies for a two-level inverter with failure of a power switch or a leg, and space vector pulse-width modulation (SVPWM) strategies have been used to control FSTPIs. However, different faulty legs correspond to different topologies of FSTPIs which are controlled by different SVPWM strategies; therefore, three SVPWM strategies need to be prepared for three FSTPIs, respectively, which takes up lots of memory space in the controller and increases the complexity of the control strategy. To overcome these disadvantages, a general SVPWM strategy that can be used to control three FSTPIs is proposed. Experimental results have shown the validity and feasibility of the proposed strategy.
  • Keywords
    PWM invertors; FSTPI; control strategy; four-switch three-phase inverters; general SVPWM strategy; post-fault reconfigured topologies; power switch; space vector pulse-width modulation strategies; two-level inverter;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el.2014.4397
  • Filename