A dual-head multi-pinhole collimator design for stationary clinical myocardial perfusion imaging
Author :
Pengyu Yan ; Mok, G.S.P. ; Chin-Hong Si ; Tsui, Benjamin M. W.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Macau, Macau, China
fYear :
2013
fDate :
Oct. 27 2013-Nov. 2 2013
Firstpage :
1
Lastpage :
3
Abstract :
Previously we designed a dual-purpose multi-pinhole (MPH) collimator for improved clinical myocardial perfusion imaging (MPI) with extra capability of small animal imaging for a clinical gamma camera. However, the standard configuration for current clinical MPI is L-mode with two detectors ~90° apart. This study aims to design a dual-head L-mode MPH collimator for potential stationary MPI based on a clinical SPECT/CT scanner. Two stationary L-mode configurations, L-mode-I/II, were proposed based on the work of Rittenbach et al. where the long axis of the left ventricle was perpendicular to either camera. With the pre-defined pinhole pattern with minimal projection truncation and <;20% multiplexing, maximum packing density and detector usage, the optimized MPH collimator parameters including pinhole number, radius-of-rotation, collimator length, aperture size and acceptance angle were determined by maximizing the sensitivity based on the pre-determined field-of-view of 20 cm and target resolution of 1 cm, considering the physical constraints of L-mode-I/II. Analytical simulations using the 4D extended cardiac-torso phantom (XCAT) were performed for 4 selected MPH designs with superior sensitivity results. Noise-free and noisy projections were generated and reconstructed using 3D MPH OS-EM algorithm. Reconstructed images were evaluated by visual assessment, normalized-mean-square-error (NMSE) and normalized standard deviation (NSD). L-mode-II generally showed less NMSE as compared to L-mode-I. For L-mode-I, 11-pinhole had the best NMSE-NSD trade-off while for L-mode-II, 18-pinhole had the best trade-off. We concluded that stationary MPI acquisition by using a dual-head MPH collimator is feasible and has the potential for dynamic MPI.
Keywords :
biomedical MRI; collimators; image reconstruction; medical image processing; phantoms; single photon emission computed tomography; 3D MPH OS-EM algorithm; 4D XCAT; 4D extended cardiac-torso phantom; MPH collimator; SPECT-CT scanner; clinical MPI; dual head multipinhole collimator design; gamma camera; maximum packing density; reconstructed images; stationary clinical myocardial perfusion imaging; target resolution; Collimators; Detectors; Image reconstruction; Noise measurement; Sensitivity; Single photon emission computed tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location :
Seoul
Print_ISBN :
978-1-4799-0533-1
Type :
conf
DOI :
10.1109/NSSMIC.2013.6829215
Filename :
6829215
Link To Document :
بازگشت