The influence of time sampling on parameters in the Logan plot
Author
Wallsten, E. ; Axelsson, Jakob ; Karlsson, Magnus ; Riklund, K. ; Nyberg, L. ; Haggstrom, Ingemar ; Larsson, A.
Author_Institution
Dept. of Radiat. Sci., Umeo Univ., Sweden
fYear
2013
fDate
Oct. 27 2013-Nov. 2 2013
Firstpage
1
Lastpage
3
Abstract
The Logan plot is a graphical method for reversible tracer bindings. The bias and uncertainties of this method have previously been analyzed with respect to noise, but little is known about the direct effects from varying the time sampling scheme. This study aims to investigate the effect of time sampling on the binding potential from the reference Logan plot. Image data from seven healthy subjects imaged with [11C]raclopride was reconstructed into six dynamic series of equal length time frames with frame times between 15 s and 480 s. Images were reconstructed using both filtered back projection (FBP) and a resolution enhanced ordered subset expectation maximization (OSEM) algorithm, SharpIR. For each sampling scheme, the nondisplaceable binding potential (BPND) parameter was calculated from the reference Logan plot with cerebellum as a reference region. The variation in BPND was analyzed as percentage deviations from the BPND for the 480 s scheme. R2 of the linear fit was also analyzed. Comparison between all sampling schemes showed that the largest deviation in BPND was 7.4% between the 15 s sampling scheme and the 480 s sampling scheme reconstructed with SharpIR. The corresponding deviation for FBP images was 1.6%. R2 was highest for long time frames, but all R2 values were above 0.997 in this study.
Keywords
expectation-maximisation algorithm; image enhancement; image reconstruction; image resolution; image sampling; medical image processing; positron emission tomography; FBP; Logan plot; OSEM; PET; SharpIR; [11C]raclopride; filtered back projection algorithm; graphical method; image reconstruction; nondisplaceable binding potential; positron emission tomography; resolution enhanced ordered subset expectation maximization algorithm; reversible tracer bindings; time sampling; Blood flow; Educational institutions; Image reconstruction; Image resolution; Noise; Positron emission tomography; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location
Seoul
Print_ISBN
978-1-4799-0533-1
Type
conf
DOI
10.1109/NSSMIC.2013.6829389
Filename
6829389
Link To Document