Abstract
We report a systematic study of detection rate capability of phenolic four-gap resistive plate chamber (RPC) in use of high-energy physics experiments. In the current study, a prototype phenolic four-gap RPCs were tested for cosmic muons and gamma rays irradiated by a 150 mCi 137Cs source. The efficiency plateau of cosmic muons measured by the four-gap RPCs with a proper threshold was about 600 V. Furthermore, the shift in the operation high voltage caused by a gamma rays background rate of 3.0 kHz cm-2 was measured as about 400 V, which was smaller than the size of the measured muon efficiency plateau. We conclude from the present study that the four-gap RPCs are capable of high-rate triggers in high-η region of the CMS experiment.
Keywords
ionisation chambers; position sensitive particle detectors; streamer chambers; CMS experiment; CMS-LHC experiment; caesium-137 source; cosmic muons; high-energy physics experiments; high-eta region; high-rate gammas; phenolic four-gap RPC tests; prototype phenolic four-gap RPC; resistive plate chamber; Detectors; Gamma-rays; Mesons; Prototypes; Size measurement; Strips; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Conference_Location
Seoul
Print_ISBN
978-1-4799-0533-1
Type
conf
DOI
10.1109/NSSMIC.2013.6829816
Filename
6829816
Link To Document