DocumentCode
701729
Title
Operation evaluations in high speed range of wound field synchronous motor drive integrated with ZSI
Author
Tajima, G. ; Kosaka, T. ; Matsui, N. ; Tonogi, K. ; Minoshima, N. ; Yoshida, T.
Author_Institution
Dept. of Comput. Sci. & Eng., Nagoya Inst. of Technol., Nagoya, Japan
fYear
2015
fDate
6-8 March 2015
Firstpage
685
Lastpage
690
Abstract
This paper presents experimental evaluations of drive performances in high-speed range of a wound field synchronous motor (WFSM) drive system integrated with a z-source inverter (ZSI). The WFSM has two field coils as DC field mmf sources instead of permanent magnets. On the other hand, the ZSI employs an impedance-network that consists of two DC reactors and two capacitors. A uniqueness of the proposed drive system lies in that this system makes it possible to reduce size and cost because the two DC reactors serve as both two field coils as the DC field mmf sources in the WFSM and the DC boosting reactors in the ZSI. The comparisons of drive performances in high-speed range between the proposed integrated system and a non-integrated system are experimentally demonstrated and discussed.
Keywords
coils; invertors; machine windings; synchronous motor drives; DC boosting reactor; WFSM drive system; ZSI; capacitor; impedance-network; integrated system; nonintegrated system; permanent magnet; wound field synchronous motor drive system; z-source inverter; Capacitors; Coils; Inverters; Synchronous motors; Torque; Voltage control; Windings; boost-up/field current control; integrated motor and drive circuit system; wound field synchronous motor; z-source inverter;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechatronics (ICM), 2015 IEEE International Conference on
Conference_Location
Nagoya
Type
conf
DOI
10.1109/ICMECH.2015.7084060
Filename
7084060
Link To Document