• DocumentCode
    7089
  • Title

    A New Isolated Auxiliary Current Pump Module for Load Transient Mitigation of Isolated/Nonisolated Step-Up/Step-Down DC–DC Converter

  • Author

    Kolluri, Sandeep ; Narasamma, N. Lakshmi

  • Author_Institution
    Dept. of Electr. Eng., Indian Inst. of Technol. Madras, Chennai, India
  • Volume
    30
  • Issue
    10
  • fYear
    2015
  • fDate
    Oct. 2015
  • Firstpage
    5991
  • Lastpage
    6000
  • Abstract
    This paper presents a new isolated auxiliary current pump module (ACPM), to improve the dynamic response of dc-dc converters under load transients. The developed isolated ACPM can be used as a generic auxiliary module for both isolated and nonisolated step-up/step-down dc-dc converters. The isolated ACPM is a low-power bidirectional converter, designed with higher bandwidth and operates only during the load transients. The performance of the developed auxiliary power converter has been evaluated in conjunction with an interleaved boost converter as main converter, which suffers from poor dynamic performance due to inherent right half plane zero effect. A suitable control scheme is designed and implemented for interleaved boost converter operating in conjunction with proposed isolated ACPM. Load current injection circuit employed in the proposed control scheme eliminates the requirement of complex nonlinear control algorithms. The proposed control scheme in particular suits for current-mode controlled converters operating along with isolated ACPM. Experimental results for a 250-W 100-kHz interleaved boost converter prototype with ACPM are presented. The peak overshoot/undershoot and the transient recovery time are reduced significantly with the incorporation of developed isolated ACPM.
  • Keywords
    DC-DC power convertors; current-mode circuits; dynamic response; electric current control; low-power electronics; nonlinear control systems; power system transients; ACPM; complex nonlinear control; current-mode controlled converters; dynamic response; frequency 100 kHz; generic auxiliary module; interleaved boost converter; isolated auxiliary current pump module; isolated-nonisolated DC-DC converter; load current injection circuit; load transient mitigation; low-power bidirectional converter; power 250 W; step-up-step-down DC-DC converter; suitable control scheme; Capacitors; DC-DC power converters; Inductors; Power system dynamics; Topology; Transient analysis; Average current-mode control (ACMC); DC-DC converter; auxiliary current pump module; auxiliary current pump module (ACPM); average currentmode control; dc???dc converter; interleaved boost converter; load current injection circuit (LCIC); load current injection circuit.; transient response;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2014.2387695
  • Filename
    7004081