DocumentCode :
709055
Title :
Eliminating non-linear RSS reporting error in a radiated RSS-based TIS testing method
Author :
Penghui Shen ; Yihong Qi ; Wei Yu ; Fuhai Li ; Jun Fan
Author_Institution :
Dept. of Electron. Sci., Hunan Univ., Changsha, China
fYear :
2015
fDate :
15-21 March 2015
Firstpage :
330
Lastpage :
334
Abstract :
A fast total isotropic sensitivity (TIS) testing method based on radiated sensitivity measurement and received signal strength (RSS) reporting is studied in this paper. An innovative method for eliminating a non-linear system error in RSS reporting is presented and incorporated into the testing procedures. Compared to the methods specified in the Cellular Telecommunications and Internet Association (CTIA) test plan, the improved fast TIS testing method can considerably reduce measurement uncertainty while maintaining the fast testing speed. Thus, it is very suitable for receiver sensitivity testing of single input single output radio systems having RSS reporting, such as cellular communication, WiFi, and bluetooth systems.
Keywords :
radio networks; radio receivers; sensitivity; testing; Bluetooth; WiFi; cellular communication; cellular telecommunications; internet association test plan; nonlinear RSS reporting error elimination; nonlinear system error elimination; radiated RSS based TIS testing method; radiated sensitivity measurement; received signal strength; total isotropic sensitivity testing method; Antenna measurements; Measurement uncertainty; Receiving antennas; Sensitivity; Testing; Uncertainty; RSS-based TIS measurement; non-linear error in RSS reporting; received signal strength (RSS); system error elimination; total isotropic sensitivity (TIS);
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility and Signal Integrity, 2015 IEEE Symposium on
Conference_Location :
Santa Clara, CA
Print_ISBN :
978-1-4799-1992-5
Type :
conf
DOI :
10.1109/EMCSI.2015.7107709
Filename :
7107709
Link To Document :
بازگشت