• DocumentCode
    715975
  • Title

    Uncertainty evaluation of 2013 TL METODE link calibration tour

  • Author

    Shinn-Yan Lin ; Yi-Jiun Huang ; Wen-Hung Tseng

  • Author_Institution
    Telecommun. Labs., Chunghwa Telecom Co., Ltd., Taoyuan, Taiwan
  • fYear
    2015
  • fDate
    12-16 April 2015
  • Firstpage
    226
  • Lastpage
    229
  • Abstract
    We targeting analyzed the UTC link delay of GPS station PTBB of PTB to TWTF of TL and expressed it as 3 groups: the uncompensated GPS common clock difference measurements, cable delay measurement, and the total delay variations of fixed GPS stations and travelling calibrator used in this METODE calibration tour. The total delay variation of fixed GPS stations PTBB and TWTF was evaluated by monitoring their long-term CCD of the same type receiver more than 350 days. For the BIPM travelling calibrator BP1C and BP0U, we used a moving cesium clock method to evaluate their instability of total delay in different antenna position. Our study was helpful for clarifying the uncertainty composition of the current PTB-TL link and could reduce it.
  • Keywords
    Global Positioning System; atomic clocks; calibration; delays; measurement standards; measurement uncertainty; 2013 TL METODE link calibration tour; GPS station PTBB; UTC link delay; cable delay measurement; cesium clock method; fixed GPS stations; total delay variations; travelling calibrator; uncertainty evaluation; uncompensated GPS common clock difference measurements; Calibration; Charge coupled devices; Delays; Global Positioning System; Receivers; Uncertainty; METODE Calibration; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium & the European Frequency and Time Forum (FCS), 2015 Joint Conference of the IEEE International
  • Conference_Location
    Denver, CO
  • Print_ISBN
    978-1-4799-8865-5
  • Type

    conf

  • DOI
    10.1109/FCS.2015.7138829
  • Filename
    7138829