Title :
Fluorescence sensor array for non-contact measurement of oxygen consumption rate of single oocyte on a microfluidic chip
Author :
Maruyama, H. ; Kito, M. ; Arai, F.
Author_Institution :
Dept. of Micro-Nano Syst. Eng., Nagoya Univ., Nagoya, Japan
Abstract :
Quality evaluation of oocyte and embryo has become one of the most important issues for many biomedical applications such as domestic animals and fertilization treatment. We developed measurement of oxygen consumption rate of individual oocyte by indirect fluorescence measurement using fluorescence oxygen sensor array having stripe-shape on a microfluidic chip. The fluorescence oxygen sensor was made of the mixture of photo-crosslinkable resin, polyethylene glycol diacrylate (PEG-DA) and Tris (2, 2´-bipyridyl) dichloro ruthenium (II) hexahydrate (Ru(bpy)3Cl2). The sensor was patterned to stripe-shape in the polydimethylsiloxane using photofabrication and molding technique. Oxygen concentration around the oocyte was distributed according to spherical diffusion theory because of similar oxygen permeability of polydimethylsiloxane and that of medium. The sensor array detects two-dimensional distribution of oxygen concentration and oxygen consumption ratio of the oocyte is calculated by image processing and Fick´s low. We demonstrated non-contact measurement of oxygen consumption ratio of single mouse oocyte on a microfluidic chip (0.59 ± 0.03 fmol/s).
Keywords :
bioMEMS; biochemistry; biodiffusion; biomedical equipment; biomedical optical imaging; biomembrane transport; chemical sensors; fluorescence spectroscopy; lab-on-a-chip; materials preparation; medical image processing; microfabrication; microfluidics; moulding; optical sensors; oximetry; pattern formation; permeability; polymer blends; quality management; resins; sensor arrays; spectrochemical analysis; veterinary medicine; Fick law; O2; PEG-DA; Ru(bpy)3Cl2; biomedical application; domestic animal treatment; embryo quality evaluation; fertilization treatment; fluorescence oxygen sensor array; image processing; indirect fluorescence measurement; medium permeability; microfluidic chip; molding; noncontact oxygen consumption rate measurement; noncontact oxygen consumption ratio measurement; oocyte oxygen consumption ratio calculation; oocyte quality evaluation; oxygen permeability; photo-crosslinkable resin mixture; photofabrication; polydimethylsiloxane permeability; polyethylene glycol diacrylate; single mouse oocyte measurement; spherical diffusion theory; stripe-shape sensor patterning; tris (2, 2´-bipyridyl) dichloro ruthenium (II) hexahydrate; two-dimensional oxygen concentration distribution detection; Biomedical measurement; Fluorescence; Microfluidics; Optical character recognition software; Oxygen; Semiconductor device measurement; Temperature measurement;
Conference_Titel :
Robotics and Automation (ICRA), 2015 IEEE International Conference on
Conference_Location :
Seattle, WA
DOI :
10.1109/ICRA.2015.7139682