DocumentCode
717352
Title
Laboratory model for active vibration control
Author
Suranek, Pavel ; Mahdal, Miroslav ; Tuma, Jiri
Author_Institution
Fac. of Mech. Eng., VSB - Tech. Univ. of Ostrava, Ostrava, Czech Republic
fYear
2015
fDate
27-30 May 2015
Firstpage
517
Lastpage
520
Abstract
This paper describes a laboratory model for experiments with an active vibration control. This test rig is consisting of steel cantilever beam connected to aluminium frame in vertical position; stack piezoactuator fixed near clamped end of the cantilever beam and a piezoelectric accelerometer positioned at the free end of the beam. Control algorithm is implemented into digital signal processing system. Experiments with suppression of several vibration modes were performed on this laboratory model.
Keywords
accelerometers; actuators; beams (structures); cantilevers; vibration control; active vibration control; aluminium frame; control algorithm; digital signal processing system; laboratory model; piezoelectric accelerometer; stack piezoactuator; steel cantilever beam; test rig; vibration mode suppression; Accelerometers; Damping; Vibrations; Welding; Active vibration control; active damping; laboratory model; piezoactuator;
fLanguage
English
Publisher
ieee
Conference_Titel
Carpathian Control Conference (ICCC), 2015 16th International
Conference_Location
Szilvasvarad
Print_ISBN
978-1-4799-7369-9
Type
conf
DOI
10.1109/CarpathianCC.2015.7145134
Filename
7145134
Link To Document