DocumentCode
721771
Title
A study on the inductance calculation of flux concentrating permanent magnet motor through non-linear magnetic equivalent circuit
Author
Lee, K. ; Hong, H. ; Oh, Y. ; Park, M.
Author_Institution
Hanyang Univ., Seoul, South Korea
fYear
2015
fDate
11-15 May 2015
Firstpage
1
Lastpage
1
Abstract
In order to design a permanent magnet synchronous motor, the inductance must be computed. In this paper, the flux concentrating permanent magnet synchronous motor (FCPMSM) is introduced. It is not easy to calculate the inductance because of the complex structure of the rotor. Because the rib and bridge consists of an iron core, they have a non-linear characteristic. In order to obtain the effective value of inductance, non-linear characteristics must be considered in magnetic equivalent circuit (MEC). In this paper, in order to calculate the inductance of FCPMSM, the relative permeance of rotor was analyzed. And then d-q axis magnetic equivalent circuit including non-linear magnetic reluctance was made up using the flux line. Finally, we verified the validity of the proposed inductance calculation method by comparing the results between the finite element method and the proposed method.
Keywords
equivalent circuits; inductance; permanent magnet motors; rotors; synchronous motors; d-q axis magnetic equivalent circuit; flux concentrating permanent magnet synchronous motor; flux line; inductance calculation; nonlinear characteristics; nonlinear magnetic equivalent circuit; nonlinear magnetic reluctance; relative permeance; rotor; Equivalent circuits; Inductance; Magnetic circuits; Magnetic flux; Permanent magnet motors; Rotors; Saturation magnetization;
fLanguage
English
Publisher
ieee
Conference_Titel
Magnetics Conference (INTERMAG), 2015 IEEE
Conference_Location
Beijing
Print_ISBN
978-1-4799-7321-7
Type
conf
DOI
10.1109/INTMAG.2015.7156999
Filename
7156999
Link To Document