DocumentCode
722392
Title
Measurement of hysteresis loop at the tip of the teeth of an inverter-driven squirrel-cage induction motor
Author
Saito, K. ; Sasayama, T. ; Nakano, M.
Author_Institution
KUBOTA Corp., Osaka, Japan
fYear
2015
fDate
11-15 May 2015
Firstpage
1
Lastpage
1
Abstract
This study presents measurements of magnetic flux and hysteresis loops in a squirrel-cage induction motor using search coils located on the tip of the teeth. Results show maximum magnetic flux near the teeth which is decreased when the motor has the rated load. This is due to armature reaction caused by the current in the rotor conductor. Hysteresis loop results indicate that the iron loss beneath the teeth increases when the motor has a load.
Keywords
magnetic flux; magnetic hysteresis; magnetic leakage; rotors; squirrel cage motors; armature reaction; hysteresis loops; inverter-driven squirrel-cage induction motor; iron loss; magnetic flux; rotor conductor; search coils; Coils; Hysteresis motors; Induction motors; Inverters; Magnetic flux; Magnetic hysteresis; Pulse width modulation;