Abstract
Wavelength-encoded tomography (WET) is upgraded to a triple-time-lens system to perform ultrafast cross-sectional imaging through 68.4x-temporal magnification. 60-MHz A-scan rate is demonstrated by imaging a glass sample with 180-μπι axial resolution.
Keywords
image coding; image resolution; lenses; optical glass; optical tomography; A-scan rate; axial resolution; frequency 60 MHz; glass sample; temporal magnification; triple-time-lens system; ultrafast cross-sectional imaging; wavelength-encoded tomography;