• DocumentCode
    74346
  • Title

    Advanced Enrichment Monitoring Technology Based on Transmission Measurements with an X-ray Source and NaI(Tl) Spectrometer

  • Author

    Ianakiev, K.D. ; Boyer, B.D. ; Goda, J.M. ; Hill, T.R. ; Moss, C.E. ; Nguyen, H. ; Parker, R.F. ; Paffett, M.T. ; Nolen, B.P. ; Swinhoe, M.T.

  • Author_Institution
    Los Alamos Nat. Lab., Los Alamos, NM, USA
  • Volume
    62
  • Issue
    3
  • fYear
    2015
  • fDate
    Jun-15
  • Firstpage
    1207
  • Lastpage
    1211
  • Abstract
    In this paper, we report our progress toward the development of an advanced enrichment monitoring technology for safeguarding gas centrifuge enrichment plants. We compare the UF6 gas pipe attenuation and sensitivity to X-ray tube HV variations for two transmission energies: 22 keV and 25.5 keV. The first experimental enrichment results taken with a static UF6 gaseous source and X-ray tube based transmission source over a wide gas pressure range are presented.
  • Keywords
    X-ray tubes; gamma-ray spectrometers; solid scintillation detectors; NaI(Tl) spectrometer; X-ray tube HV variations; X-ray tube-based transmission source; advanced enrichment monitoring technology; electron volt energy 22 keV; electron volt energy 25.5 keV; static UF6 gaseous source; transmission energies; transmission measurements; Attenuation; Electron tubes; Monitoring; Sensitivity; Temperature measurement; Temperature sensors; Transmission line measurements; Enrichment monitoring; GCEP; uranium hexafluoride; x-ray tube;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2015.2424697
  • Filename
    7111383