    Residual Amplitude Modulation Method Implemented at the Phase Quadrature Frequency of a 1650-nm Laser Diode for Line Shape Recovery of Methane

  • Author

    Upadhyay, Ankit ; Chakraborty, Arup Lal

  • Author_Institution
    Dept. of Electr. Eng., Indian Inst. of Technol. Gandhinagar (IITGN), Gandhinagar, India
  • Volume
    15
  • Issue
    2
  • fYear
    2015
  • fDate
    Feb. 2015
  • Firstpage
    1153
  • Lastpage
    1160
  • Abstract
    This paper reports the extraction of concentration and pressure of methane using a 1650-nm laser diode operated at its phase quadrature frequency (fq) and using the calibration-free residual amplitude modulation (RAM) method. Although the RAM method is the simplest calibration-free technique, it has low signal levels compared with the phasor decomposition (PD) method for small values of the phase difference ψ between the laser intensity modulation and frequency modulation (FM). For the laser diode used in this paper, ψ turned out to be 90° at a very modest modulation frequency of 125.5 kHz, which is an order of magnitude lower than values reported elsewhere. The RAM signal and FM signal are at phase quadrature at this frequency and each can be fully and simultaneously recovered along a detection axis of a lock-in amplifier free from distortion by the other. The absolute absorption profile is accurately recovered with the signal-to-noise ratio (SNR) maximized for this laser. The gas parameters are extracted by fitting a Voigt line shape to the experimental data. These results show that when operating at fq, the PD method offers no advantage over the RAM method and is therefore redundant. In addition, the background RAM is eliminated by an automatic fiber-optic RAM nulling technique. Finally, the RAM method is also implemented at high values of modulation index to increase the SNR ratio. The time resolution of measurements is currently 10 s. The prospect of using the RAM method with a 2004-nm vertical cavity surface emitting laser is also explored.
  • Keywords
    amplitude modulation; frequency modulation; intensity modulation; light absorption; optical fibre amplifiers; optical modulation; organic compounds; phase modulation; semiconductor lasers; surface emitting lasers; FM signal; PD method; SNR; Voigt line shape recovery; automatic fiber-optic RAM nulling technique; calibration-free residual amplitude modulation method; concentration extraction; frequency 125.5 kHz; frequency modulation; gas parameter extraction; laser diode; laser intensity modulation; lock-in amplifier detection; methane; phase quadrature frequency; phasor decomposition method; pressure extraction; signal-to-noise ratio; time 10 s; vertical cavity surface emitting laser; wavelength 1650 nm; wavelength 2004 nm; Absorption; Frequency modulation; Laser tuning; Random access memory; Shape; Vertical cavity surface emitting lasers; Calibration-free; VCSEL; methane; phasor decomposition method; residual amplitude modulation; tunable diode laser spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2014.2358714
  • Filename
    6901260