Title :
Comparison of two impulse calibrators with a high-resolution digitizer
Author :
Li, Yi ; Hällström, Jari K. ; Lucas, Wolfgang
Author_Institution :
Nat. Meas. Lab., Lindfield, NSW, Australia
fDate :
4/1/2005 12:00:00 AM
Abstract :
The lightning impulse voltage calibrators, developed at National Measurement Laboratory (NML) and MIKES-HUT, and a recently developed commercial digitizer were compared. With this three-way comparison, not only the accuracies of the devices were compared, but also the linearity of measurement of both peak voltage and time parameters was investigated. The results demonstrated that the linearity of the calibrators is superior to that of the digitizer.
Keywords :
analogue-digital conversion; calibration; measurement standards; voltage measurement; MIKES-HUT; National Measurement Laboratory; commercial digitizer; comparison measurements; high-resolution digitizer; lightning impulse voltage calibrators; measurement linearity; peak voltage parameter; time parameters; Attenuators; Australia; Circuits; DC generators; Impedance measurement; Laboratories; Lightning; Linearity; Time measurement; Voltage measurement; Calibrators; comparison measurements; digitizers; lightning impulse voltage;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.2004.843375