DocumentCode :
747752
Title :
Comparison of two impulse calibrators with a high-resolution digitizer
Author :
Li, Yi ; Hällström, Jari K. ; Lucas, Wolfgang
Author_Institution :
Nat. Meas. Lab., Lindfield, NSW, Australia
Volume :
54
Issue :
2
fYear :
2005
fDate :
4/1/2005 12:00:00 AM
Firstpage :
608
Lastpage :
611
Abstract :
The lightning impulse voltage calibrators, developed at National Measurement Laboratory (NML) and MIKES-HUT, and a recently developed commercial digitizer were compared. With this three-way comparison, not only the accuracies of the devices were compared, but also the linearity of measurement of both peak voltage and time parameters was investigated. The results demonstrated that the linearity of the calibrators is superior to that of the digitizer.
Keywords :
analogue-digital conversion; calibration; measurement standards; voltage measurement; MIKES-HUT; National Measurement Laboratory; commercial digitizer; comparison measurements; high-resolution digitizer; lightning impulse voltage calibrators; measurement linearity; peak voltage parameter; time parameters; Attenuators; Australia; Circuits; DC generators; Impedance measurement; Laboratories; Lightning; Linearity; Time measurement; Voltage measurement; Calibrators; comparison measurements; digitizers; lightning impulse voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2004.843375
Filename :
1408245
Link To Document :
بازگشت