DocumentCode
748328
Title
Development of multichannel dual-mixer time difference system to generate UTC (NICT)
Author
Nakagawa, Fumimaru ; Imae, Michito ; Hanado, Yuko ; Aida, Masanori
Author_Institution
Nat. Inst. of Inf. & Commun. Technol., Tokyo, Japan
Volume
54
Issue
2
fYear
2005
fDate
4/1/2005 12:00:00 AM
Firstpage
829
Lastpage
832
Abstract
A multichannel dual-mixer time difference (DMTD) system has been developed by the National Institute of Information and Communications Technology (NICT) for a measurement system to generate the UTC(NICT) time scale based on Coordinated Universal Time (UTC). This system measures time differences between a reference signal and 24 device under test (DUT) signals, simultaneously. We have confirmed that this system has enough accuracy to measure hydrogen maser and cesium clocks at an averaging time of 1 s.
Keywords
measurement standards; mixers (circuits); time measurement; National Institute of Information and Communications Technology; cesium clocks; coordinated universal time; device under test signals; hydrogen maser; measurement system; multichannel dual-mixer time difference system; time measurement; Atomic clocks; Atomic measurements; Communications technology; Frequency measurement; Hydrogen; Masers; Phase measurement; Stability; System testing; Time measurement; Time measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2004.843382
Filename
1408299